G.4.13 – Aluminium Framed Windows Installation Issues – Part 1

Introduction: Window is a building component, which is generally used for closing an opening in a wall that will admit light and may provide ventilation and views to the building occupants. Windows are typically factory produced unit that has one or more openings bounded by a perimeter frame. Performance of a window may be assessed …

G.4.13 – Aluminium Framed Windows Installation Issues – Part 1 Read More »

G.4.12 – Stick Curtain Wall Installation Issues Part 3

Introduction: Curtain wall is one of the most common façade systems that is used in modern building envelopes. In accordance with CWCT Standard for systemised building envelopes “Curtain walling is a form of predominantly vertical building envelope which supports no load other than its own weight and the environmental forces which act upon it”. The …

G.4.12 – Stick Curtain Wall Installation Issues Part 3 Read More »

G.4.11 – Stick Curtain Wall Installation Issues Part 2

Introduction: Curtain wall is one of the most common façade systems that is used in modern building envelopes. In accordance with CWCT Standard for systemised building envelopes “Curtain walling is a form of predominantly vertical building envelope which supports no load other than its own weight and the environmental forces which act upon it”. The …

G.4.11 – Stick Curtain Wall Installation Issues Part 2 Read More »

G.4.10 – Stick Curtain Wall Bracket Installation Issues

Introduction: Curtain wall is one of the most common façade systems that is used in modern building envelopes. In accordance with CWCT Standard for systemised building envelopes “Curtain walling is a form of predominantly vertical building envelope which supports no load other than its own weight and the environmental forces which act upon it”. The …

G.4.10 – Stick Curtain Wall Bracket Installation Issues Read More »

G.4.9 – Safety Concerns of Fragile Rooflight

Introduction: This article has been written by one of our façade engineers, following a non-intrusive investigation of “Fragile” or “Class 3” rooflight in accordance with CWCT Technical Note No. 66. The main purpose of this investigation was to evaluate the current condition of the rooflights and to provide a commentary on ways in which to …

G.4.9 – Safety Concerns of Fragile Rooflight Read More »

G.4.2 – Terracotta Cladding Detachment

Introduction: This article has been authored by one of our façade engineers following a non-intrusive investigation of some of the loose/detaching terracotta cladding tiles, together with a review of the available Operation & Maintenance (O&M) documentation. This article consists of our engineer’s comments on the construction details, probable cause(s) of terracotta tiles becoming loose, potential …

G.4.2 – Terracotta Cladding Detachment Read More »

G.4.8 – Rainscreen Fire Investigation (1)

Introduction: This article has been written by one of our façade engineers, following an intrusive investigation of the external cladding system of the residential building, in order to understand the external cladding assemblies and to determine which elements will need to be replaced to meet building requirements and enhance the fire performance of the façade. …

G.4.8 – Rainscreen Fire Investigation (1) Read More »